Database Reference: NIST Structural Ceramics Database, SRD Database Number 30.
Journal Reference:
Elastic Moduli Data for Polycrystalline Ceramics, R. G. Munro, NISTIR 6853, (2002),Other Materials: Elastic Moduli Data
National Institute of Standards and Technology,
Gaithersburg, Maryland 20899.
Other Materials Properties: Property Data Summaries
|
Ref. Nbr. |
Exhibit Type |
Exhibit Number |
Value Type |
Measurement Method |
Matl. Nbr. |
T [°C] |
d [g/cm3] |
p [%] |
VL [km/s] |
VS [km/s] |
E [GPa] |
G [GPa] |
B [GPa] |
nu |
Table Notes |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 185 | Text | 904 | x | ultrasonic resonance | 1 | 23 | 5.802 | 222 | 1 | ||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 23 | 5.802 | 222 | 1 | ||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 225 | 213 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 308 | 194 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 413 | 179 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 523 | 178 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 612 | 178 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 714 | 178 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 802 | 179 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 900 | 179 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 1014 | 179 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 1111 | 178 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 1217 | 176 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 1297 | 172 | 1 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 1 | 1343 | 170 | 1 | |||||||
| 185 | Text | 904 | x | ultrasonic resonance | 2 | 23 | 5.878 | 223 | 2 | ||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 23 | 5.878 | 222 | 2 | ||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 120 | 217 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 212 | 211 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 308 | 187 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 413 | 178 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 519 | 177 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 608 | 178 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 718 | 180 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 798 | 180 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 904 | 180 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 1014 | 180 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 1115 | 179 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 1221 | 177 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 1301 | 174 | 2 | |||||||
| 185 | Graph | 2 | x | ultrasonic resonance | 2 | 1356 | 171 | 2 |
Privacy Statement/Security Notice
Disclaimer | FOIA
NIST is an agency of the
U.S. Commerce Department
Date created: 24 October 2002
Last updated: 24 October 2002
Technical inquiries:
Ceramics Division
NIST, 100 Bureau Drive, Stop 8520, Gaithersburg, MD 20899-8520.
Phone (301) 975-6119
Fax (301) 975-5334
Ceramics website comments:
Ceramics Webmaster
General NIST inquiries:
Public Inquiries Unit:
Phone (301) 975-NIST (6478)
TTY (301) 975-8295