AD-999 ( Al2O3 )

Reference: NIST Technical Note

Reference: NIST Structural Ceramics Database

Note: About Property Data Summaries.

Note: Abbreviations and Other Notes

Note: Other Materials


Material Summary:

[Ref. 1,2,3,4,5,6] Manufacturer........: Coors Porcelain Co. Material Designation: AD-999 Material Form.......: Polycrystal Composition.........: 99.9% Al2O3 (mass fraction) Processing..........: Sintered

References:

[1] L. A. Simpson, "Microstructural Considerations for the Application of Fracture Mechanics Techniques" Fracture Mechanics of Ceramics, Vol. 2, pp. 567-577 (1974). [2] G. R. Anstis, P. Chantikul, B. R. Lawn, and D. B. Marshall, "A Critical Evaluation of Indentation Techniques for Measuring Fracture Toughness: I, Direct Crack Measurements" Journal of the American Ceramic Society, Vol. 64, No. 9, 533-538 (1981). [3] L. M. Baker, "Short Rod K(Ic) Measurements of Al2O3" Fracture Mechanics of Ceramics, Vol. 3, pp. 483-493 (1973). [4] G. D. Swanson, "Fracture Energies of Ceramics" Journal of the American Ceramic Society, Vol. 55, No. 1, 48-49 (1972). [5] C.A. Tracy and G.D. Quinn, "Fracture Toughness by the Surface Crack in Flexure (SCF) Method," Ceramic Engineering and Science Proceedings, Vol. 15, pp. 837-845 (1994). [6] R. J. Gettings and G. D. Quinn, "Surface Crack in Flexure (SCF) Measurements of the Fracture Toughness of Advanced Ceramics," Ceramic Engineering and Science Proceedings, Vol. 16, pp. 539-544 (1995)

Property Table:

Temperature = 23 °C Grain Porosity Fracture Fracture Measurement Measurement Comments Size Toughness Energy Method Environment [µm] [%] [MPa·m1/2] [J/m2] ------ -------- ------------ --------- ----------- ----------- ---------------------------- 3 19.7 SENB air Ref. 1 19.05 DCB ---------------------------------------------------------------------------------------------------- 3 3.9 DCB Ref. 2; E = 406 GPa 3.32 ICS E = 386 GPa 3.09 IS E = 386 GPa ---------------------------------------------------------------------------------------------------- 3 [1-6] 3.12 SR Ref. 3; E = 386 GPa ---------------------------------------------------------------------------------------------------- 3 24.3 DCB Ref. 4; E = 386 GPa ---------------------------------------------------------------------------------------------------- <10 3.6 SCF Ref. 5; E = 401 GPa ---------------------------------------------------------------------------------------------------- 3.39 SCF air Ref. 6; E = 386 GPa, nu = 0.21, density = 3.96 g/cm3 --------------------------------------------------------------------------------------------------------



Privacy Statement/Security Notice
Disclaimer | FOIA

NIST is an agency of the
U.S. Commerce Department

Date created: 08 February 2001
Last updated: 08 February 2001


Technical inquiries:
Ceramics Division
NIST, 100 Bureau Drive, Stop 8520, Gaithersburg, MD 20899-8520.
Phone (301) 975-6119
Fax (301) 975-5334

Ceramics website comments:
Ceramics Webmaster

General NIST inquiries:
Public Inquiries Unit:
Phone (301) 975-NIST (6478)
TTY (301) 975-8295